Mazzei AirJection System

How it Works:

  1. Odors caused by septic conditions can be prevented by maintaining aerobic conditions with dissolved oxygen concentrations of 0.5 mg/l or less.

  2. An oxygen uptake rate (OUR) can be used to estimate the required oxygen transfer rate. Typical OUR values for odor control are between 0.5 mg/l-hr and 2.0 mg/l-hr (see Test Data below).

  3. The oxygen transfer requirement is calculated by multiplying the mass of the water in the pond (or lagoon or basin) by the OUR.

Test Data:

_________________________________________________

Click to see more information about each application below:

1 Sewer Main Aeration 3 Activated Sludge Aeration 5 Post Aeration
2 Odor Control 4 Pure Oxygen Injection 6 Sludge Digestion
7 Ozone Disinfection

1-Sewer Main Aeration 2-Odor Control 3-Aeration 4-Pure Oxygen 5-Post Aeration 6-Sludge Digestion 7-Ozone for Disinfection


Look for The Mazzei® Design . . . Because It's What's Inside That Matters!

Click to Find Out More About Mazzei Injectors Technical Support Staff                           Same-Day Shipping                           High Quality Materials - PVDF, ECTFE, 316L Stainless Steel                           Continued Customer Support                           Experienced Engineers                           Patented Technology                           Quality Products                           Over 27 Years in Business
 

 

The Mazzei Look is a three-dimensional registered trademark.